An Introduction to EPEVER UPOWER Series Inverter/Chargers
Inverters are employed to convert the DC power to AC power, providing the required voltage and frequency at the output. Inverters can be considered as power adapters. So they are considered as one of the important parts of a photovoltaic system, which supplies AC power for any appliance.
Charge controllers are also utilized to convert the solar energy from the panels to electricity, which is essential to charge the batteries in a PV system. Solar chargers get the electricity from the solar panels and control for everything, to make sure that the batteries are charged most efficiently and healthily.
Sometimes, the amount of energy absorbed by the solar panels is not enough to charge the battery for the proper operation of household appliances. Therefore, an additional source of energy is necessary to provide energy for the photovoltaic system. A hybrid charger/inverter puts the operation of an inverter and a charge controller together which is an all in one solution. However, this is not the only advantage of hybrid devices. In this article, we will get to know more about hybrid inverter/chargers and their advantages.
As mentioned, the inverter converts DC (battery) power into AC power and then passes it along to the appliances. An inverter/charger does the same; however, it is also capable of receiving the charge from external AC sources. When the input AC power is unavailable, a hybrid inverter/charge switches to battery mode. This is similar to Uninterrupted Power Suppliers (UPS) functions.
The UPOWER series of EPEVER is a new type of so-called inverter/chargers, combining the solar & utility/ external AC input and provide means for a more reliable solar off-grid system.
UPOWER, adopts a multi-core processor design and an advanced MPPT control algorithm to enhance the capabilities of the solar set. It has the features:
- High response speed
- High reliability and
- High industrialization standard.
It offers four charging modes including:
- Solar priority
- Utility priority
- Solar and
- Utility & Solar
Two output modes for Battery and Utility enables this device to meet various application demands. The up-to-date optimized MPPT tracking technology is adopted for the PV charging modules. It can quickly track the maximum power point of the PV array in any environment and acquire the maximum energy of solar panels in real-time.
The advanced control algorithm is adopted for AC-DC charging modules. It realizes fully digitalized double closed-loop control for voltage and current, with high a high accuracy control system.
The input range of AC voltage is wide enough to cover different types of sources. The output DC charging voltage/current is continuously adjustable in a certain range, and the complete input/output protection functions can offer a stable and reliable charging profile and charging protection for the batteries. This feature will lead to high charging conversion efficiency, which is more than 98% in all types of EPEVER UPOWER series. Besides, the power loss is minimized by the efficient AC-DC conversion. The DC-AC module is based on full digital and intelligent design. It adopts the advanced SPWM technology, resulting in a pure sine wave output and converts 24/48VDC to 220/230VAC, suitable for AC loads of household appliances, electric tools, commercial units, electronic audio, and video devices, etc.
The product adopts a 4.2-inch LCD display design, which displays real-time operational data and parameters. Comprehensive electronic protection functions ensure the highest level of safety and stability.
Figure 1- EPEVER UPowe Series Inverter/Charger
Features of EPEVER UPOWER Series Inverter/Charger
In this section, we will introduce the features of UPOWER series, which make them a proper choice for cold and cloudy climate conditions. Such places suffer from lack of a clear sky or sunny days, so for home appliances, which need solar power to work, an additional power source is necessary. UPOWER series benefit from the additional power sources, which can be an AC utility or power generator. The prominent feature of the UPOWER series is to combine the external AC power with solar power to enhance the reliability of the system. In places with higher rates of cloudy sky, it’s not efficient enough to use the external generator all the time in terms of cost and maintenance. This ensures efficient use of the solar system while reducing the run time and costs of external power sources. Cold and cloudy climate conditions restrict the application of solar energy in noticeable parts of the year, so the external AC power source or electrical generator provides energy for the household appliances when the amount of solar energy is not enough for the proper performance of the appliances.
Some of the main features of EPEVER UPOWER Series Inverter/Chargers are highlighted here which implies the priorities of these inverter/chargers over conventional ones:
- Adoption of the advanced SPWM technology, with pure sine wave output.
- Fully digitalized voltage and current double closed-loop control.
- Advanced MPPT technology, with efficiency no less than 99.5%.
- Advanced control algorithm, with efficiency no less than 98%.
- LCD design that enables the realtime display of system operating status.
- Provided with common interface and advanced interface.
- Multiple LED indicators instantly indicate the operating state of the system.
- 2P circuit breaker provided at the utility input end.
- Independent control of AC output by AC OUT button.
- Battery temperature compensation function.
- Extensive Electronic protection.
Structure of the EPEVER UPOWER Series Inverter/Charger
In this section, the structure of UPOWER series inverter/chargers and their various ports and terminals will be discussed to help the proper operation and wiring of solar systems.
u | Ventilation | { | Relay interface |
v | Captive screw (2 pcs) | | | Remote interface |
w | AC output terminals | } | Inverter/charger switch |
x | Utility input terminals | ~ | PV input terminals |
y | Battery input terminals | ⓫ | Terminals cover |
z | RTS★ interface |
1- Ventilation: UPOWER adapts a smart temperature controlled cooling fan, helping the system to remain in a reasonable temperature range. However, external ventilation is highly recommended if the device is mounted in an enclosure. Thus, it should never be installed in an enclosure with flooded batteries! Battery fumes from vented batteries will corrode and destroy the inverter/charger circuits.
2- Captive screws: It helps to open the enclosure to get access to the main interface of its PCB.
3- AC output terminals: The protected AC outputs of the device. The protections are: Utility input overvoltage and Utility input under-voltage
4- Utility input terminals, which are protected.
5- Battery input terminals: which are protected against Battery overvoltage and battery over-discharge
6- RTS interface remote temperature sensor enables the system to activate the protection mode against battery overheating.
7- Relay interface: Smart relay interface, which switches the external AC generator ON based on the current battery capacity.
8- Remote interface: To turn ON and off the inverter remote.
9- Inverter/Charger switch: This turns the system ON/OFF.
10- PV input terminals: which are protected. These protections are PV limit Current, PV short circuit, PV Reverse Polarity, Night Reverse Charging.
11- Is the terminals cover
Models:
UPOWER models follow a very simple rule for naming, which is clear in the following picture.
Schematic Diagram for Connections of EPEVER UPOWER Series Inverter/Charger
Figure 2- schematic diagram of connections in UPOWER series
PV array
Absorbs the sun’s power and passes it to the MPPT charge controller to charge the batteries.
Utility
This is the additional AC power source to charge the batteries. When the source is not available, the UPOWER switches to battery power. This utility can be any external source of power in urban applications, while for off-grid systems, an external power generator can provide the energy. The AC output voltage of the UPOWER is in the range of 220-230 VAC. This means that the urban power distribution network with the 220-230 VAC output voltage can be utilized as the direct AC power source for the EPEVER UPOWER. This is called the “bypass function.”
Battery
UPOWER is compatible with various types of batteries, including AGM, Gel, Flooded, etc. However, the charging parameters are fully customizable to meet the charging profile of any kind of batteries.
AC load
Any AC consumer is considered as an AC load.
Installation steps
This section includes the installation guideline of the EPEVER UPOWER series inverter/charger.
Step1:Determination of Installation Location and heat-dissipation Space
Determination of installation location: The inverter/charger shall be installed in a place with sufficient airflow through the dissipation pad of the inverter/charger and a minimum clearance of 150 mm from the upper and lower edges of the device to ensure natural thermal convection.
Step 2: Remove the terminal protective cover
Step 3:Wiring
Follow the wiring scheme of UPOWER as described in below picture:
Grounding
Grounding must be applied when the utility is connected to the inverter/charger. The inverter/charger has a dedicated grounding terminal, as shown in picture above. The grounding wire has to stay consistent with the recommended wire for AC output. Grounding point shall be as close as possible to the inverter/charger, the grounding wire shall be as short as possible, and if it’s not possible, its recommended to increase the wire size accordingly.
AC output, Ground and PV wiring terminals
When wiring, do not close the circuit breaker, and it is necessary to use a slotted screwdriver to unscrew the screws for connecting their corresponding wires.
When removing the wirings, first turn the UPOWER off, and then the screws shall be unscrewed by using a slotted screwdriver, so as to dismantle their corresponding wires.
Step 4: Install the terminal protective cover.
Step 5:Connect accessory
Connect the remote temperature sensor cable.
Step 6:Recheck if the wire connection is correct
Step 7:Power on the inverter/charger
Interface Instruction
In this section, we will discuss the interface of the EPEVER UPOWER series. Indicators and buttons on the screen of the inverter/charger are investigated through subsequent tables:
Indicator | Color | Status | Instruction |
Green | OFF | No utility input | |
On Solid | Utility connection normal but no charging | ||
Slowly Flashing(0.5Hz) | Utility charging | ||
Fast Flashing(2.5Hz) | Utility charge module fault | ||
Green | OFF | No PV input | |
On Solid | PV connection normal but no charging | ||
Slowly Flashing(0.5Hz) | PV charging | ||
Fast Flashing(2.5Hz) | PV charge module fault | ||
Green | OFF | Inverter turns off | |
On Solid | Inverter turn on Bypass | ||
Slowly Flashing(0.5Hz) | Inverter output | ||
Fast Flashing(2.5Hz) | Inverter fault | ||
Green | OFF | No-load output | |
On Solid | Load output | ||
Green | OFF | Relay turns off | |
On Solid | Relay turn on | ||
Green | OFF | Input voltage(3.3~12VDC) | |
On Solid | No Input voltage | ||
Green | OFF | Inverter output | |
Slowly Flashing(0.5Hz) | Utility output | ||
Red | OFF | Device normal | |
On Solid | Device fault |
Buttons:
Operation | instruction |
Press the button | Exit the current interface |
Press the button and hold on 2s | Clear the faults |
Press the or button | Browse interface: Up/Down |
Setting interface: Up/Down | |
Press the button | Switch to “Browse Parameter Column” Confirm the setting parameters |
Press the button and hold on 2s | Switch the” Real-Time Interface” over to “Set Browse Interface” |
Switch the “Set Browse Interface” over to “Parameter Setting Interface” | |
Press the button and hold on 2s | Inverter ON/OFF |
As mentioned before, one of the prominent characteristics of the UPOWER series is various operating modes. Here we discuss these modes in both input and output parameters. First, we start from the input parameters.
Input priorities:
Solar priority (default)
The battery is charged in solar priority mode, and when the battery voltage is lower than “Auxiliary Module ON Voltage (VAON),” the utility starts charging. When the battery voltage reaches to “Auxiliary Module OFF Voltage (VAOF),” the utility stops charging.
Utility priority
The battery is charged in utility priority mode, and when the battery voltage is lower than “Auxiliary Module ON Voltage (VAON),” the solar starts charging. When the battery voltage reaches to “Auxiliary Module OFF Voltage (VAOF),” the solar stops charging.
Utility & solar
Utility &solar charge the battery means that both utility and solar panels produce energy to charge the battery simultaneously, and the battery will be charged by both power sources.
Solar
In this mode, battery is charged by the solar panel, and utility is not available. The solar panel absorbs the energy and flows it to the battery.
Output Priorities
Battery
Utility (default)
As the final section, we discuss the other functions which are available by the UPOWER series inverter/charger.
Output voltage & frequency switch:
When Switch 1 is in “ON”, the output voltage is selected as 230VAC, and on the contrary as 220VAC.
When Switch 2 is in “ON”, the output frequency is selected as 60Hz, and on the contrary as 50Hz.
The switches are illustrated in the figure below.
NOTE: If the output frequency or voltage of the inverter/charger is to be reset, it is required to turn off the inverter/charger and power on the unit after setting.
Technical Specification of EPEVER UPOWER Series Inverter/Charger:
Item | UP1000-M3212 | UP1000-M3222 | UP1500-M3222 | UP2000-M3322 | UP3000-M3322 | UP3000-M6322 | ||
System battery voltage | 12VDC | 24VDC | ||||||
Battery input voltage range | 10.8~16VDC | 21.6~32VDC | ||||||
Inverter Output | ||||||||
Continuous output power | 800W | 800W | 1200W | 1600W | 2400W | 2400W | ||
Output power (15min.) | 1000W | 1000W | 1500W | 2000W | 3000W | 3000W | ||
Overload power(5s) | 1600W | 1600W | 2400W | 3200W | 4800W | 4800W | ||
Max. surge power | 2000W | 2000W | 3000W | 4000W | 6000W | 6000W | ||
Output voltage range | 220VAC±3%, 230VAC (-7%~+3%) | |||||||
Output frequency | 50Hz/60Hz | |||||||
Output wave | Pure Sine Wave | |||||||
Distortion THD | ≤3% (12V or 24V resistive load) | |||||||
Inverter efficiency | 91% | 94% | 95% | 95% | 95% | 95% | ||
Transfer time | 20mS | |||||||
Utility Input | ||||||||
Utility input voltage range | 160VAC~280VAC(Working voltage range) 170VAC~270VAC(Utility starting voltage range) | |||||||
Max. utility charge current | 20A | 20A | 20A | 30A | 30A | 30A | ||
Solar Charging | ||||||||
Max. PV open circuit voltage | 60V★ 46V◆ | 100V★ 92V◆ | 150V★ 138V◆ | |||||
Max. PV input power | 390W | 780W | 780W | 780W | 780W | 1500W | ||
Max. PV charging current | 30A | 30A | 30A | 30A | 30A | 60A | ||
Equalization voltage | 14.6V | 29.2V | ||||||
Boost voltage | 14.4V | 28.8V | ||||||
Float voltage | 13.8V | 27.6V | ||||||
Tracking efficiency | ≤99.5% | |||||||
Charging conversion efficiency | ≤98% | |||||||
Temperature compensate coefficient | -3mV/℃/2V (Default) | |||||||
Others | ||||||||
No-load consumption | ≤1.2A | ≤0.6A | ≤0.6A | ≤0.8A | ≤0.8A | ≤0.8A | ||
Enclosure | IP30 | |||||||
Relative humidity | < 95% (N.C.) | |||||||
Working environment temperature | -20℃~50℃(100% input and output) | |||||||
Mechanical Parameters | ||||||||
Dimension | 386×300×126mm | 444×300×126mm | 518×310×168mm | |||||
Mounting dimension | 230mm | |||||||
Mounting hole size | Φ8mm | |||||||
Weight | 7.3kg | 7.3kg | 7.4kg | 8.5kg | 9.2kg | 14.9kg |
★At minimum operating environment temperature
◆At 25℃ environment temperature
Item | UP3000-M3212 | UP3000-M3222 | UP5000-M3222 | UP5000-M3322 | UP5000-M3322 | |||
System battery voltage | 48VDC | |||||||
Battery input voltage range | 43.2~64VDC | |||||||
Inverter Output | ||||||||
Continuous output power | 2400W | 2400W | 4000W | 4000W | 4000W | |||
Output power (15min.) | 3000W | 3000W | 5000W | 5000W | 5000W | |||
Overload power(5s) | 4800W | 4800W | 8000W | 8000W | 8000W | |||
Max. surge power | 6000W | 6000W | 10000W | 10000W | 10000W | |||
Output voltage range | 220VAC±3%, 230VAC (-7%~+3%) | |||||||
Output frequency | 50Hz/60Hz | |||||||
Output wave | Pure Sine Wave | |||||||
Distortion THD | ≤3% (24V or 48V resistive load) | |||||||
Inverter efficiency | 95% | |||||||
Transfer time | 20mS | |||||||
Utility Input | ||||||||
Utility input voltage range | 160VAC~280VAC(Working voltage range) 170VAC~270VAC(Utility starting voltage range) | |||||||
Max. utility charge current | 15A | 15A | 30A | 30A | 30A | |||
Solar Charging | ||||||||
Max. PV open circuit voltage | 150V 138V | 200V★ 180V◆ | ||||||
Max. PV input power | 1040W | 3000W | 3000W | 4000W | 5000W | |||
Max. PV charging current | 20A | 60A | 60A | 80A | 100A | |||
Equalization voltage | 58.4V | |||||||
Boost voltage | 57.6V | |||||||
Float voltage | 55.2V | |||||||
Tracking efficiency | ≤99.5% | |||||||
Charging conversion efficiency | ≤98% | |||||||
Temperature compensate coefficient | -3mV/℃/2V (Default) | |||||||
Others | ||||||||
No-load consumption | ≤0.6A | ≤0.6A | ≤0.8A | ≤0.8A | ≤0.8A | |||
Enclosure | IP30 | |||||||
Relative humidity | < 95% (N.C.) | |||||||
Working environment temperature | -20℃~50℃(100% input and output) | |||||||
Mechanical Parameters | ||||||||
Dimension | 444×300×126mm | 518×310×168mm | 614×315×178mm | |||||
Mounting dimension | 230mm | |||||||
Mounting hole size | Φ8mm | |||||||
Weight | 7.3kg | 14.7kg | 16.6kg | 17.5kg | 17.8kg |
Good Morning. I need the PIN assignment of the RS485 RJ45 interface to connect the inverter to my home automation system.
Thank you and best regards. Thomas Hesse
Hi,
Thanks for reaching out.
Please send us an email to ” helpdesk [at] epsolarpv.com ” and my colleagues in the technical support department will provide you with the RS485 interface information.
Hello. Can the epever upower series 1000w be mounted flat on its back? (i.e. with the controls facing upwards). Thanks.
Der Laderegler Trancer 3210 A zeigt das Nachtsymbol, soll aber die Bordbatterien des Wohnwagens, der in einem durchsichtig überdachtem K-Port überwintert erhalten. Es sind 4 X 100 Watt Panel unter dem Durchsichtigen Dach installiert. Bisher kam mein Sonneneinstrahlung das normale Symbol und den Panel – Zeichen. Vielen Dank und freundliche Grüße Gerhard Paschinsky (paschinsky@t-online.de)
Hi! We’ve recently bought one UP3000-M6322 charger-inverter.
Can you clarify if Max. utility charge current of 30A in Tech. specification concerns the AC side (220V AC) or the DC side (24V DC) of the converter?
Thanks a lot
Hello Petros,
Max. utility charge current is the charging current from grid.It is AC.
Alo, boa tarde.
Acabei de instalar um sistema com inversor Upower 5000-HM8042 e baterias Lítio Pylontech US2000C. O sistema ja está a funcionar, mas a baterias fica a dar som beep a cada 30 segundos.
Mas não mostra sinal Alarme no indicador luz ( Alarm) nas baterias.
Quero saber como resolver este problema…Qualquee ajuda será útil.
Hi Sir, thanks for reaching us. In this case, the issue might come from the battery side’s voltage, current, or temperature. We suggest you could first check the battery’s manual. Please feel free to contact us anytime if that still couldn’t solve.
deseo precio del controlador solar mppt y los datos de su representante en MERIDA MEXICO
Y SI PUEDEN ENVIARLO A MEXIC
GRACIAS
hello sir, please send your demand to info[at]epever.com, our team who are in charge of sales will contact you.
How about Residual Current Breaker?
Hello Marcos, If the neutral line of the AC output is grounding. and you need to use RCB.
bonjours
j’ai un up5000 m10342, je dispose de deux batterie ( Batterie Lithium 2.4kWh – US2000 – Pylontech)
et des que les voyants vert sont fixe il y a une coupure de courant voir même de disjoncter, sans consommer de trop une machine a laver .
pouvez vous me dire quoi faire.
merci salutation
Hi, thanks for reaching out. But can you describe your question in more details, it’s better in English, thanks.
Hi. I just installed a UPower-Hi UP5000-HM8042. The manual refers to the “Auxiliary Module On/Off” (AON/AOF), what is the Auxiliary Module?
Hi Dave, thanks for your comments. The Auxiliary module actually means the utility. UPower-Hi supports utility charging and solar charging (the charging mode can be adjusted), in the solar priority charging mode, PV charges the battery. When the battery voltage is lower than VON, the utility charges the battery as a supplement; When the battery voltage is higher than AOF, the utility stops charging the battery.
Why the Charger don’t respect VAON and VAOFF voltage limits by input mode set to “Solar priority”, when PV voltage is OFF or drop to 0V (during night time)?
Hi sir, thanks for reaching us. Solar energy priority means that solar energy is the main charge. When the battery voltage drops to auxiliary charging, the utility will charge, otherwise will not charge.
Yes, I agree. But this is true ONLY when the PV voltage is >0 V.
If the PV voltage drops to zero, the UPower starts to charge the battery from the utility and doesn’t respect any auxiliary limits.
This is completely illogical behavior and there is no information about it in the user manual.
Hello , I own an epever up1000 M3212 , the battery status is ” battery error ” , the battery i am sure 100% is not damage , what could be the problem ?
Hi Daniel, thanks for reaching out. Our technician has sent you an email about the question. Please check and contact them if you have further questions.
Pozdravljeni
pred kratkim sem kupil epever -UPower model UP5000-M8342 (PK) zanima me, če se črtice za prikaz polnjenja akumulatorja ustavijo, ko je akumulator pol na samem ekranu mi kaže akumulator 100% poln a se črtice, ki prikazujejo polnjenje kljub temu ne ustavijo..imam svinčene ciklične akumulatorje (FLD) 8X 12v 230 ah kakšne nastavitve mi priporoćate. Hvala
Hi Sir, thanks for your comments. EPEVER inverter/charger SOC(state of charge) follows the below formula:
SOC=100%*(X-LVD)/(FCV-LVD). LVD means Low voltage disconnect voltage (default 11.1V/12V system, can change); FCV means Float charging voltage (default 13.8V/12V system, can change); X means current voltage. You can change the “Low voltage Disconnect Voltage” and “Float Charging Voltage” to adjust the SOC value. However, this SOC is not 100% accurate to show the battery’s real remaining. Our controller does not have the ability to calculate the exact value of SOC, which is in our future plan for updated controllers, and inverter/chargers. If you have further questions, please feel free to ask here, or you could send an email to support@epever.com, thanks!
I am using an UP3000-HM5042 and I reached the PV input power limit. Is it possible to use two of these inverters in parallel with the same battery and same load? Or if it is not possible can I use a TRACER 6420AN to charge the same battery?
Thanks
Hi Zoltan, thanks for reaching us. It’s not available to execute for 2 of your questions.
Hi, what is the smallest size generator I can use for utility power on a UP3000-M6322.
Hi, thanks for reaching out. We suggest using larger than 4000W.
My 3kw epever hybrid inverter utility can’t charge battery upto 25V voltage but solar mppt charge very well upto 28V. I used AGM batterys. Inverter doesn’t have a any error code. Please let me how to fix it. Settings are ok. Before 8 months inverter working very well.
Please help me hardware / software fixes
Model: UP3000-HM10022 RTU
Hi Ashan, thanks for your questions. If your charging mode is PV priority, the utility would as an assistant, the charging would stop when it reaches a certain voltage. You can adjust to Utility & Solar mode to ensure the PV and utility charging.
Hi. Can I connect 2 batteries to Up1000-3212?
Hi sir, thanks for reaching out. The voltage of the UP-1000-3212 battery is 12V. If both batteries are 12V, they can be connected in parallel
Hi,
can any upower device work without any battery connected, so leveraging only the utility and solar input to provide power to loads ?
Thank you very much,
Hi Sir, the upower should work with battery, otherwise, the upower will make no sense in the solar system.